Ductless mini-splits

Carrier Performance 26 37MARA Single-Zone Ductless System

Carrier 37MARAQ09AA3Factory Authorized Dealer network 50% data complete
Price not yet sourced
we haven't found a defensible price

Installed price varies far more by contractor and zone count than by brand — get real quotes, and see the equipment-only price on this product's own page.

Carrier-badged single-zone ductless system built on the Carrier Midea North America joint-venture platform, not an in-house Carrier design.

Our take

Worth stating plainly, the way this catalog already discloses the Daikin/Goodman platform-sharing on the heat-pump side: Carrier's residential ductless line comes out of Carrier Midea North America, a 2017 joint venture, not Carrier's own ducted-system engineering group. That doesn't make it a bad product, but it does mean the Carrier name here means less than it does on Carrier's ducted Infinity line.

Best for

Buyers already committed to a Carrier dealer relationship who want ductless from the same account.

Watch out for

Carrier ductless equipment is sold through a closed dealer network — expect to get a quote rather than a public price, and expect the same dealer-network lock-in this catalog already flags for Carrier's ducted line.

How it performs by climate zone

Heating capability against each zone's 99% winter design temperature.

ZoneDesign tempVerdict
3C — Warm – Marine 36°F Strong fit Rated to -13°F, comfortably below this zone's 36°F design temperature.
4A — Mixed – Humid 14°F Strong fit Rated to -13°F, comfortably below this zone's 14°F design temperature.
4B — Mixed – Dry 18°F Strong fit Rated to -13°F, comfortably below this zone's 18°F design temperature.
4C — Mixed – Marine 27°F Strong fit Rated to -13°F, comfortably below this zone's 27°F design temperature.
5A — Cool – Humid 2°F Strong fit Rated to -13°F, comfortably below this zone's 2°F design temperature.
5B — Cool – Dry 3°F Strong fit Rated to -13°F, comfortably below this zone's 3°F design temperature.
6A — Cold – Humid -8°F Workable Rated to -13°F against a -8°F design temperature — enough margin, though backup heat will run on the coldest days.
6B — Cold – Dry -10°F Marginal Rated to -13°F with a -10°F design temperature leaves almost no margin. Expect backup heat to carry a meaningful share of the load.
7 — Very Cold -20°F Not suitable Rated only to -13°F, but this zone's design temperature is -20°F.
8 — Subarctic -40°F Not suitable Rated only to -13°F, but this zone's design temperature is -40°F.

Compare against

Before you buy this

Ask the contractor for the AHRI certificate number for the specific indoor/outdoor combination being installed — ratings apply to matched pairs, not to the outdoor unit alone. Ask whether they will perform a Manual J load calculation rather than sizing off the equipment being replaced. And check your state and utility incentive programmes: there is no federal tax credit for a 2026 installation, so those programmes are now the only incentive money available, and many require approval before installation.