Central air conditioners

Cooling-only systems paired with a separate furnace or air handler.

Buyer's guide: How to choose a central air conditioner 9 min →

We hold full sourced data on 12 central air conditioners, each with a specification traced to its source and cross-checked against owner reports.

Specific features Optional

Voltage filters only equipment with a sourced indoor-unit match. Confirm the exact AHRI combination and electrical requirements before buying.

All the central air conditioners we have data on

Ranked by our objective durability read until you tell us about your house. Click through for full specifications with sources.

Durability Strong

Rheem Endeavor Line Prestige RA19AYRA19AY60AJVCA / UA19AY60AJVCA

Current Rheem/Ruud R-454B 5-ton communicating inverter condenser. Rheem's designated test combination with the RHMVY6021SEACAJ modulating air handler delivers 54,000 BTU/h, 17.5 SEER2 and 10.5 EER2.

Cooling (SEER2)17.5
Cooling (EER2)10.5
Size54,000 BTU/h
from ~$12,000 installed · est.
Full details →
Durability Strong

Rheem Endeavor Line Classic Plus RA16AYRA16AY60AJ2NA / UA16AY60AJ2NA

Current Rheem/Ruud R-454B 5-ton, two-stage cooling-only condenser. It is the middle Rheem/Ruud replacement path between single-stage equipment and the fully communicating inverter system.

Cooling (SEER2)17
Cooling (EER2)12
Size56,000 BTU/h
from ~$8,500 installed · est.
Full details →
Durability Strong

Carrier Infinity24ANB1

Variable-speed cooling-only condenser, SEER2 up to 21, designed to pair with a gas furnace.

Cooling (SEER2)21
Cooling (EER2)13.5
Size36,000 BTU/h
from ~$7,000 installed · est.
Full details →
Durability Strong

Trane XV20i4TTV0

Variable-speed cooling-only condenser rated to SEER2 20.5, built around Trane's Climatuff compressor.

Cooling (SEER2)20.5
Cooling (EER2)13
Size36,000 BTU/h
from ~$6,800 installed · est.
Full details →
Durability Strong

Bryant Preferred 148TAN148TAN04800W

Two-stage cooling-only condenser, SEER2 18, EER2 14, built on the same Puron Advance platform Carrier sells as its own mid-tier line.

Cooling (SEER2)18
Cooling (EER2)14
Size48,000 BTU/h
Full details →
Durability Strong

Lennox Merit ML14KC1ML14KC1-018

Entry-tier single-stage cooling-only condenser, SEER2 up to 17, sized for a small home or condo.

Owners: 1 watch-out 2 reports →
Cooling (SEER2)17
Size17,000 BTU/h
Full details →
Durability Solid

Rheem Endeavor Line Classic RA13NYRA13NY24AJ1NA

Single-stage cooling-only condenser, SEER2 13.4 — just above the current federal minimum, Rheem's builder-grade entry tier.

Owners: 1 watch-out 3 reports →
Cooling (SEER2)13.4
Cooling (EER2)9
Size24,000 BTU/h
Full details →
Durability Strong

Daikin DX5SEDX5SEA3010A

Single-stage cooling-only condenser, R-410A, SEER2 up to 17 — Daikin's economy tier, engineered on the same platform as sibling brand Amana's ASXH4.

Owners: 1 watch-out 1 report →
Cooling (SEER2)17
Size30,000 BTU/h
from ~$3,500 installed · est.
Full details →
Durability Solid

Goodman GSXC18GSXC180241

Two-stage cooling-only condenser, R-410A, SEER2 17 — being sold through as clearance inventory ahead of Goodman's move to R-32/R-454B.

Owners: 1 watch-out 2 reports →
Cooling (SEER2)17
Size24,000 BTU/h
Full details →
Durability Solid

Goodman GSXC18GSXC180481

Two-stage cooling-only condenser, R-410A, SEER2 18, the 4-ton entry in Goodman's outgoing GSXC18 clearance line.

Owners: 1 watch-out 2 reports →
Cooling (SEER2)18
Size48,000 BTU/h
Full details →
Durability Solid

York Affinity YXTYXT48B21S

Two-stage cooling-only condenser, SEER2 18, R-410A — York's mid-tier line, a step below its full variable-speed YXV.

Cooling (SEER2)18
Size48,000 BTU/h
Full details →
Durability Strong

Goodman GLXS4BGLXS4BA3010

Two-stage cooling-only condenser on R-32 — Goodman's newer refrigerant platform, ahead of most of the market's move to R-454B.

Owners: 1 watch-out 1 report →
Cooling (SEER2)14.5
Size30,000 BTU/h
Full details →

What the specifications mean

SEER2

Seasonal Energy Efficiency Ratio 2 -- cooling output over a season divided by electricity used, measured under the 2023 DOE test procedure.

The headline cooling efficiency number. SEER2 replaced SEER in 2023 and uses a higher external static pressure, so SEER2 figures run roughly 4-5% lower than the old SEER for the same equipment. Never compare a SEER number to a SEER2 number.

EER2

Energy Efficiency Ratio 2 — cooling output divided by power draw at a single hot operating point (95°F outdoor).

SEER2 is a seasonal average measured at 82°F. In a desert climate your afternoons are far hotter than that, so EER2 — measured at 95°F — describes what the equipment does when you actually need it. In hot-dry climates, weight EER2 above SEER2.

Rated capacity (BTU/h)

Nominal heating or cooling output at the standard rating condition.

Sizing matters more than efficiency. An oversized system short-cycles, fails to dehumidify, and wears out early. Always size from a Manual J load calculation.

Durability is read from objective signals only — the weakest link in the warranty, the refrigerant's service outlook, and what trade and owner reports say about parts and service. How we research →  ·  Comparing whole system types, not just this category? Run the recommender →